Paramonga Design Key Points and Difficulties of Steel Structure Spiral Stairs
Design Key Points and Difficulties of Steel Structure Spiral Stairs
Paramonga
Paramonga I. Design Key Points
Paramonga 1. Structural Safety
Paramonga - Load Calculation: It is necessary to consider static loads (self-weight), live loads (usage by people, furniture handling, etc.) and dynamic loads (vibration, wind loads, etc.), and it should meet the requirements of the *Code for Loads on Building Structures*.
Paramonga
- Support System: The selection of the central column type, cantilever type or double-helix structure directly affects the stability. The bending and torsional resistance capabilities need to be verified through finite element analysis (FEA).
Paramonga
Paramonga - Node Design: The connection nodes between the tread plate and the central column/side beam need to avoid stress concentration. Welding or high-strength bolt connections should be adopted, and fatigue checking should be carried out.
Paramonga 2. Optimization of Geometric Parameters
Paramonga - Spiral Parameters: Determine the relationship among the rotation radius (R), rotation angle (θ) and pitch (H), and avoid the tread height (h) and depth (d) exceeding the comfortable range for the human body (it is recommended that h = 15 - 20 cm, d ≥ 25 cm).
Paramonga
Paramonga - Slope Control: The slope of the spiral staircase is usually relatively steep (45° - 60°). Anti-slip tread plates need to be set or intermediate rest platforms need to be added (suitable for large-scale spiral staircases).
Paramonga
3. Coordination between Space and Function
Paramonga - Passage Width: The difference between the inner diameter and the outer diameter needs to meet the minimum passage width (≥ 60 cm for a single person, ≥ 90 cm for two people) to avoid the risk of collisions when going up and down.
Paramonga
- Clear Height: The vertical clear height inside the spiral needs to be ≥ 2 m to avoid users hitting their heads.
Paramonga
Paramonga 4. Selection of Materials and Processes
Paramonga
- Selection of Steel: It is recommended to use Q355B or higher-strength steel. For highly corrosive environments, hot-dip galvanized steel or weathering steel should be used.
Paramonga
- Surface Treatment: The anti-slip texture (such as checkered steel plates, anti-slip coatings) and the anti-rust treatment of the railing (spraying or electrophoresis process) need to be designed simultaneously.
Paramonga
Paramonga II. Design Difficulties
Paramonga
Paramonga 1. Complex Stress Analysis
Paramonga
- Torque and Lateral Force: The spiral structure will generate torque and lateral thrust when loaded. Nonlinear analysis needs to be carried out through 3D modeling software (such as ANSYS or Rhino + Karamba).
Paramonga
Paramonga - Resonance Risk: The natural frequency of the steel structure needs to avoid the human walking frequency range (1.6 - 2.4 Hz) to prevent potential safety hazards caused by resonance.
Paramonga
Paramonga 2. Precise Machining and Installation
Paramonga
- 3D Curved Surface Molding: The bending accuracy of the spiral beam needs to be controlled within ±2 mm. A numerically controlled plate rolling machine or grinding after segmented welding should be used.
Paramonga
Paramonga - On-site Assembly Error: The positioning deviation of the embedded parts will lead to overall deviation. Virtual pre-assembly needs to be carried out through BIM technology, and adjustment devices (such as adjustable supports) should be reserved.
Paramonga
Paramonga 3. Conflict between Norms and Humanization
Paramonga - Tread Uniformity: The tread height of the spiral staircase may vary due to the change of the radius. It is necessary to maintain uniformity by using tapered treads or adjusting the rotation angle.
Paramonga
Paramonga - Railing Continuity: The smooth transition of the curved railing and the handrail needs to take into account both aesthetics and the comfort of gripping. It is recommended to use parametric modeling to optimize the curvature.
Paramonga 4. Adaptability to Special Scenarios
Paramonga
Paramonga - Fire Evacuation: It needs to meet the requirements of the *Code for Fire Protection Design of Buildings* for the width and fire resistance limit of the evacuation staircase (for example, the outdoor staircase needs to have a fire resistance of more than 1.5 hours).
Paramonga
Paramonga - Barrier-free Design: If barrier-free passage is required, it is necessary to locally add platforms or adopt a gentle slope spiral structure, but this will significantly increase the floor area.
Paramonga
Paramonga
III. Examples of Solutions
Paramonga
Case 1: Cantilevered Spiral Staircase
Paramonga Use box-section steel beams as cantilever supports, and share the torque through diagonal tie rods to reduce the space occupied by the central column.
Paramonga Case 2: Modular Prefabrication
Paramonga
Split the staircase into standardized tread units, and connect them with bolts on site after prefabrication in the factory, reducing the construction difficulty and cost.
Paramonga
Paramonga
Paramonga
Paramonga IV. Summary
Paramonga
The core of the design of the spiral staircase lies in balancing the mechanical performance and the space experience, and it is necessary to achieve the unity of function and aesthetics through multi-disciplinary collaboration (structure, architecture, construction). It is recommended to give priority to the following work in the scheme stage:
Paramonga 1. Establish a parametric model to verify the geometric feasibility;
2. Conduct a 1:10 local node physical test;
Paramonga 3. Communicate with the construction party in advance about the limitations of the processing technology.

Paramonga
发表评论